  1.                          SECTION 05731
  2.  
  3.                   ORNAMENTAL ALUMINUM COLUMNS
  4. NOTE ** Moultrie Manufacturing Company ornamental aluminum
  5.         columns.
  6. NOTE **
  7. NOTE ** This section is based on products manufactured by
  8.         Moultrie Manufacturing Company, located at the
  9.         following address:
  10. NOTE **      Moultrie GA 31768
  11. NOTE **      Tel:  (800) 841-8674
  12. NOTE **
  13. NOTE ** Moultrie Manufacturing Company offers a complete
  14.         line of ornamental aluminum columns, as well as
  15.         ornamental metal railing systems.
  16. NOTE **
  17. NOTE ** SECTION 05731 - ORNAMENTAL ALUMINUM COLUMNS,
  18.         Copyright 1997, The Architect's Catalog, Inc.
  19.  
  20. PART 1  GENERAL
  21.  
  22. 1.1 SECTION INCLUDES
  23.  
  24.     A.  Aluminum Columns.
  25.  
  26.     B.  Aluminum Column Capitals.
  27.  
  28.     C.  Aluminum Column Bases.
  29.  
  30. 1.2 RELATED SECTIONS
  31. NOTE ** Delete any sections below not relevant to this
  32.         project; add others as required.
  33.  
  34.     A.  Section 05120 - Structural Steel.
  35.  
  36.     B.  Section 05500 - Metal Fabrications.
  37.  
  38.     C.  Section 06100 - Rough Carpentry.
  39.  
  40.     D.  Section 06400 - Architectural Woodwork.
  41.  
  42.     E.  Section 09900 - Paints and Coatings.
  43.  
  44. 1.3 REFERENCES
  45.  
  46.     A.  ASTM B 179 - Standard Specification for Aluminum Alloys
  47.         in Ingot Form for Castings from All Casting Processes.
  48.  
  49.     B.  ASTM B 221 - Standard Specification for Aluminum and
  50.         Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and
  51.         Tubes.
  52.  
  53.     C.  ASTM B 221M - Standard Specification for Aluminum and
  54.         Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and
  55.         Tubes (Metric).
  56.  
  57. 1.4 SUBMITTALS
  58.  
  59.     A.  Submit under provisions of Section 01300.
  60.  
  61.     B.  Product Data:  Manufacturer's descriptive literature for
  62.         specified components; indicate compliance to specified
  63.         requirements.
  64.  
  65.     C.  Shop Drawings:  Indicate locations, sizes, and heights of
  66.         columns; include construction and installation details,
  67.         and interface with adjacent construction.
  68. NOTE ** Delete the following two paragraphs if specifying
  69.         primer-finished items.
  70.  
  71.     D.  Verification Samples:
  72.         1.  One (1) column section, minimum size 12 inches  (300
  73.             mm) long by diameter of specified column, with
  74.             specified capital and base, representing actual color
  75.             and finish of products to be installed.
  76. NOTE ** Retain one of the following three sub-paragraphs.
  77.         2.  Return samples of capital and base to manufacturer
  78.             when so directed by Architect, or at project
  79.             closeout.
  80.         3.  Accepted samples of capital and base may be
  81.             incorporated into Work as last units of type.
  82.         4.  Samples will be retained by Architect.
  83.  
  84.     E.  Quality Assurance Submittals:
  85.         1.  Design Data:  Loading calculations for columns,
  86.             bearing seal and signature of structural engineer
  87.             licensed to practice in the State in which the
  88.             project is located.
  89.         2.  Certificates:
  90.             a.  Contractor's certification that installer meets
  91.                 specified qualifications.
  92.             b.  Manufacturer's certification that installer is
  93.                 approved.
  94.         3.  Manufacturer's Instructions:  Printed installation
  95.             instructions for each product, including product
  96.             storage requirements and instructions for bracing and
  97.             shoring of adjacent construction.
  98.  
  99. 1.5 QUALITY ASSURANCE
  100.  
  101.     A.  Installer Qualifications:  Minimum three (3) years
  102.         documented experience installing products specified in
  103.         this section, and approved by manufacturer.
  104.  
  105. 1.6 DELIVERY, STORAGE, AND HANDLING
  106.  
  107.     A.  Store products of this section in manufacturer's unopened
  108.         packaging until installation.
  109.  
  110.     B.  Maintain storage area conditions for products of this
  111.         section in accordance with manufacturer's instructions
  112.         until installation.
  113.  
  114. 1.7 PROJECT CONDITIONS
  115.  
  116.     A.  Field Measurements:  When construction schedule permits,
  117.         take field measurements at locations where columns are to
  118.         be installed prior to ordering components.
  119.  
  120. PART 2  PRODUCTS
  121.  
  122. 2.1 MANUFACTURERS
  123.  
  124.     A.  Acceptable Manufacturer:  Moultrie Manufacturing Company,
  125.         Moultrie GA 31768.  ASD. Telephone (800) 841-8674.
  126. NOTE ** Delete one of the two following paragraphs;
  127.         coordinate with Division 1 requirements.
  128.  
  129.     B.  Requests for substitution will be considered in
  130.         accordance with provisions of Section 01600.
  131.  
  132.     C.  Substitutions:  Not permitted.
  133. NOTE ** Delete following paragraph if substitutions not
  134.         permitted.
  135.  
  136.     D.  Unless otherwise specified for an individual product or
  137.         material, supply all products specified in this section
  138.         from the same manufacturer.
  139.  
  140. 2.2 COMPONENTS
  141. NOTE ** Retain the following paragraph to specify square
  142.         columns; if more than one type, size, or finish is
  143.         required, assign a type to each, duplicate
  144.         paragraph and edit for each.  Coordinate types with
  145.         drawings.
  146.  
  147.     A.  Square Column Assemblies:
  148.         1.  Column:  Fabricated staves of extruded aluminum
  149.             conforming to ASTM B 221/ASTM B 221M, Alloy 6063,
  150.             Temper T6; with snap-fitting vertical seams for field
  151.             assembly:
  152. NOTE ** Retain one of the following four sub-paragraphs to
  153.         specify square column style.
  154.             a.  Style:  Old South Traditional Square Column,
  155.                 fluted vertical faces.
  156.             b.  Style:  Old South Federal Square Column, flat
  157.                 vertical faces.
  158.             c.  Style:  Old South Square Plantation Column,
  159.                 single-indent vertical faces.
  160.             d.  Style:  Old South Square Plantation Column,
  161.                 double-indent vertical faces.
  162. NOTE ** Retain one of the following six sub-paragraphs to
  163.         specify size and load-bearing capacity of column.
  164.             e.  Size:  3 inches ( 76 mm) square; 10,000 pounds (
  165.                 4,530 kg) load-bearing capacity.
  166.             f.  Size:  4 inches (101 mm) square; 15,000 pounds (
  167.                 6,795 kg) load-bearing capacity.
  168. NOTE ** The above sizes available for Traditional Square
  169.         Column only.
  170.             g.  Size:  6 inches (152 mm) square; 22,000 pounds (
  171.                 9,966 kg) load-bearing capacity.
  172.             h.  Size:  8 inches (203 mm) square; 30,000 pounds
  173.                 (13,590 kg) load-bearing capacity.
  174.             i.  Size:  10 inches (254 mm) square; 30,000 pounds
  175.                 (13,590 kg) load-bearing capacity.
  176.             j.  Size:  12 inches (305 mm) square; 30,000 pounds
  177.                 (13,590 kg) load-bearing capacity.
  178. NOTE ** Retain one of the following two sub-paragraphs to
  179.         specify column length.
  180.             k.  Column length:  __ feet __ inches (__ m).
  181.             l.  Column length:  Indicated on drawings.
  182.  
  183.         2.  Capital and base:  Cast of aluminum conforming to
  184.             ASTM B 179; size for slip-fit over column:
  185. NOTE ** Retain one of the following three sub-paragraphs to
  186.         specify capital for square columns.
  187.             a.  Capital:  Standard square.
  188.             b.  Capital:  Architectural square.
  189.             c.  Capital:  Architectural II square.
  190. NOTE ** Retain one of the following three sub-paragraphs to
  191.         specify base for square columns.
  192.             d.  Base:  Standard square.
  193.             e.  Base:  Architectural square.
  194.             f.  Base:  Architectural II square.
  195. NOTE ** Retain one of the following six sub-paragraphs to
  196.         specify column, capital, and base finish.
  197.         3.  Finish:  Factory primer.
  198.         4.  Finish:  Factory baked-on powder coat enamel, White
  199.             color.
  200.         5.  Finish:  Factory baked-on powder coat enamel,
  201.             Alabaster color.
  202.         6.  Finish:  Factory baked-on powder coat enamel, Biscuit
  203.             color.
  204.         7.  Finish:  Factory baked-on powder coat enamel, Clay
  205.             color.
  206.         8.  Finish:  Factory baked-on powder coat enamel, Brown
  207.             color.
  208. NOTE ** Retain the following paragraph to specify round
  209.         columns.
  210.  
  211.     B.  Round Column Assemblies:
  212.         1.  Column:  Fabricated staves of extruded aluminum
  213.             conforming to ASTM B 221/ASTM B 221M, Alloy 6063,
  214.             Temper T6; with snap-fitting vertical seams for field
  215.             assembly:
  216.             a.  Style:  Old South Round Column, fluted vertical
  217.                 faces.
  218. NOTE ** Retain one of the following nine sub-paragraphs to
  219.         specify size and load-bearing capacity of column.
  220.             b.  Size:  5 inches (127 mm) diameter; 16,000 pounds
  221.                 ( 7,248 kg) load-bearing capacity.
  222.             c.  Size:  6 inches (152 mm) diameter; 22,000 pounds
  223.                 ( 9,966 kg) load-bearing capacity.
  224.             d.  Size:  8 inches (203 mm) diameter; 29,000 pounds
  225.                 (13,137 kg) load-bearing capacity.
  226.             e.  Size:  10 inches (254 mm) diameter; 21,000 pounds
  227.                 ( 9,513 kg) load-bearing capacity.
  228.             f.  Size:  12 inches (305 mm) diameter; 28,000 pounds
  229.                 (12,684 kg) load-bearing capacity.
  230.             g.  Size:  15 inches (381 mm) diameter; 31,000 pounds
  231.                 (14,043 kg) load-bearing capacity.
  232.             h.  Size:  18 inches (457 mm) diameter; 31,000 pounds
  233.                 (14,043 kg) load-bearing capacity.
  234.             i.  Size:  24 inches (609 mm) diameter; 31,000 pounds
  235.                 (14,043 kg) load-bearing capacity.
  236. NOTE ** Consult with manufacturer for data for 36-inch
  237.         diameter column.
  238.             j.  Size:  36 inches (914 mm) diameter; __,___ pounds
  239.                 (__,___ kg) load-bearing capacity.
  240. NOTE ** Retain one of the following two sub-paragraphs to
  241.         specify column length.
  242.             k.  Column length:  __ feet __ inches (__ m).
  243.             l.  Column length:  Indicated on drawings.
  244.         2.  Capital and base:  Cast of aluminum conforming to
  245.             ASTM B 179; size for slip-fit over column:
  246. NOTE ** Retain one of the following four sub-paragraphs to
  247.         specify capital for round columns.
  248.             a.  Capital:  Standard round.
  249.             b.  Capital:  Doric round.
  250.             c.  Capital:  Corinthian round.
  251.             d.  Capital:  Scamozzi round.
  252. NOTE ** Retain one of the following two sub-paragraphs to
  253.         specify base for round columns.
  254.             e.  Base:  Standard round.
  255.             f.  Base:  Doric round.
  256. NOTE ** Retain one of the following six sub-paragraphs to
  257.         specify column, capital, and base finish.
  258.         3.  Finish:  Factory primer.
  259.         4.  Finish:  Factory baked-on powder coat enamel, White
  260.             color.
  261.         5.  Finish:  Factory baked-on powder coat enamel,
  262.             Alabaster color.
  263.         6.  Finish:  Factory baked-on powder coat enamel, Biscuit
  264.             color.
  265.         7.  Finish:  Factory baked-on powder coat enamel, Clay
  266.             color.
  267.         8.  Finish:  Factory baked-on powder coat enamel, Brown
  268.             color.
  269. NOTE ** Delete the following paragraph if not required for
  270.         project.
  271.  
  272.     C.  As indicated on shop drawings, provide column sections,
  273.         capital, and base fabricated in split components for
  274.         retro-fit installation; provide for concealed fastening
  275.         of split component halves.
  276.  
  277.     D.  Accessories:  Provide accessories specified in
  278.         manufacturer's instructions or indicated on shop
  279.         drawings, including, but not limited to, lally columns,
  280.         load distribution plates, angle clips, and fasteners.
  281.  
  282.  
  283. PART 3  EXECUTION
  284.  
  285. 3.1 EXAMINATION
  286.  
  287.     A.  Verify that heights of locations to receive columns are
  288.         in accordance with shop drawings.
  289.  
  290.     B.  Installer's Examination:
  291.         1.  Have installer of this section examine conditions
  292.             under which construction activities of this section
  293.             are to be performed, then submit written notification
  294.             if such conditions are unacceptable.
  295.         2.  Transmit two copies of installer's report to
  296.             Architect within 24 hours of receipt.
  297.         3.  Beginning construction activities of this section
  298.             before unacceptable conditions have been corrected is
  299.             prohibited.
  300.         4.  Beginning construction activities of this section
  301.             indicates installer's acceptance of conditions.
  302.  
  303. 3.2 PREPARATION
  304.  
  305.     A.  Shore and brace adjacent construction in accordance with
  306.         manufacturer's instructions.
  307.  
  308. 3.3 INSTALLATION
  309.  
  310.     A.  Install components in accordance with shop drawings and
  311.         manufacturer's installation instructions.
  312.  
  313.     B.  Remove shoring and bracing immediately after completion
  314.         of column installation.
  315.  
  316.     C.  Site Tolerances:
  317.         1.  Maximum variation from indicated location:  1/4 inch
  318.             (6 mm).
  319.         2.  Maximum variation from plumb:  1/4 inch (6 mm) in 10
  320.             feet (3 m).
  321. NOTE ** Delete the following paragraph if components are
  322.         factory finished.
  323.  
  324.     D.  Field Finishing:  Specified in Section 09900.
  325.  
  326. 3.4 CLEANING
  327.  
  328.     A.  Clean component finishes in accordance with
  329.         manufacturer's instructions immediately after
  330.         installation; protect finishes from soiling until
  331.         Substantial Completion.
  332.  
  333. 3.5 PROTECTION
  334.  
  335.     A.  Protect components and component finishes from damage by
  336.         subsequent construction activities until Substantial
  337.         Completion.
  338.  
  339.     B.  Repair damage in accordance with manufacturer's
  340.         recommendations; replace units which cannot be repaired
  341.         to Architect's acceptance.
  342.  