home
***
CD-ROM
|
disk
|
FTP
|
other
***
search
/
Spec Disk 1998 Spring 4.0
/
Spec Disk 1998 Spring 4.0.iso
/
text
/
05731mmc.txt
< prev
next >
Wrap
Text File
|
1998-06-10
|
14KB
|
345 lines
SECTION 05731
ORNAMENTAL ALUMINUM COLUMNS
NOTE ** Moultrie Manufacturing Company ornamental aluminum
columns.
NOTE **
NOTE ** This section is based on products manufactured by
Moultrie Manufacturing Company, located at the
following address:
NOTE ** Moultrie GA 31768
NOTE ** Tel: (800) 841-8674
NOTE **
NOTE ** Moultrie Manufacturing Company offers a complete
line of ornamental aluminum columns, as well as
ornamental metal railing systems.
NOTE **
NOTE ** SECTION 05731 - ORNAMENTAL ALUMINUM COLUMNS,
Copyright 1997, The Architect's Catalog, Inc.
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Aluminum Columns.
B. Aluminum Column Capitals.
C. Aluminum Column Bases.
1.2 RELATED SECTIONS
NOTE ** Delete any sections below not relevant to this
project; add others as required.
A. Section 05120 - Structural Steel.
B. Section 05500 - Metal Fabrications.
C. Section 06100 - Rough Carpentry.
D. Section 06400 - Architectural Woodwork.
E. Section 09900 - Paints and Coatings.
1.3 REFERENCES
A. ASTM B 179 - Standard Specification for Aluminum Alloys
in Ingot Form for Castings from All Casting Processes.
B. ASTM B 221 - Standard Specification for Aluminum and
Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and
Tubes.
C. ASTM B 221M - Standard Specification for Aluminum and
Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and
Tubes (Metric).
1.4 SUBMITTALS
A. Submit under provisions of Section 01300.
B. Product Data: Manufacturer's descriptive literature for
specified components; indicate compliance to specified
requirements.
C. Shop Drawings: Indicate locations, sizes, and heights of
columns; include construction and installation details,
and interface with adjacent construction.
NOTE ** Delete the following two paragraphs if specifying
primer-finished items.
D. Verification Samples:
1. One (1) column section, minimum size 12 inches (300
mm) long by diameter of specified column, with
specified capital and base, representing actual color
and finish of products to be installed.
NOTE ** Retain one of the following three sub-paragraphs.
2. Return samples of capital and base to manufacturer
when so directed by Architect, or at project
closeout.
3. Accepted samples of capital and base may be
incorporated into Work as last units of type.
4. Samples will be retained by Architect.
E. Quality Assurance Submittals:
1. Design Data: Loading calculations for columns,
bearing seal and signature of structural engineer
licensed to practice in the State in which the
project is located.
2. Certificates:
a. Contractor's certification that installer meets
specified qualifications.
b. Manufacturer's certification that installer is
approved.
3. Manufacturer's Instructions: Printed installation
instructions for each product, including product
storage requirements and instructions for bracing and
shoring of adjacent construction.
1.5 QUALITY ASSURANCE
A. Installer Qualifications: Minimum three (3) years
documented experience installing products specified in
this section, and approved by manufacturer.
1.6 DELIVERY, STORAGE, AND HANDLING
A. Store products of this section in manufacturer's unopened
packaging until installation.
B. Maintain storage area conditions for products of this
section in accordance with manufacturer's instructions
until installation.
1.7 PROJECT CONDITIONS
A. Field Measurements: When construction schedule permits,
take field measurements at locations where columns are to
be installed prior to ordering components.
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Acceptable Manufacturer: Moultrie Manufacturing Company,
Moultrie GA 31768. ASD. Telephone (800) 841-8674.
NOTE ** Delete one of the two following paragraphs;
coordinate with Division 1 requirements.
B. Requests for substitution will be considered in
accordance with provisions of Section 01600.
C. Substitutions: Not permitted.
NOTE ** Delete following paragraph if substitutions not
permitted.
D. Unless otherwise specified for an individual product or
material, supply all products specified in this section
from the same manufacturer.
2.2 COMPONENTS
NOTE ** Retain the following paragraph to specify square
columns; if more than one type, size, or finish is
required, assign a type to each, duplicate
paragraph and edit for each. Coordinate types with
drawings.
A. Square Column Assemblies:
1. Column: Fabricated staves of extruded aluminum
conforming to ASTM B 221/ASTM B 221M, Alloy 6063,
Temper T6; with snap-fitting vertical seams for field
assembly:
NOTE ** Retain one of the following four sub-paragraphs to
specify square column style.
a. Style: Old South Traditional Square Column,
fluted vertical faces.
b. Style: Old South Federal Square Column, flat
vertical faces.
c. Style: Old South Square Plantation Column,
single-indent vertical faces.
d. Style: Old South Square Plantation Column,
double-indent vertical faces.
NOTE ** Retain one of the following six sub-paragraphs to
specify size and load-bearing capacity of column.
e. Size: 3 inches ( 76 mm) square; 10,000 pounds (
4,530 kg) load-bearing capacity.
f. Size: 4 inches (101 mm) square; 15,000 pounds (
6,795 kg) load-bearing capacity.
NOTE ** The above sizes available for Traditional Square
Column only.
g. Size: 6 inches (152 mm) square; 22,000 pounds (
9,966 kg) load-bearing capacity.
h. Size: 8 inches (203 mm) square; 30,000 pounds
(13,590 kg) load-bearing capacity.
i. Size: 10 inches (254 mm) square; 30,000 pounds
(13,590 kg) load-bearing capacity.
j. Size: 12 inches (305 mm) square; 30,000 pounds
(13,590 kg) load-bearing capacity.
NOTE ** Retain one of the following two sub-paragraphs to
specify column length.
k. Column length: __ feet __ inches (__ m).
l. Column length: Indicated on drawings.
2. Capital and base: Cast of aluminum conforming to
ASTM B 179; size for slip-fit over column:
NOTE ** Retain one of the following three sub-paragraphs to
specify capital for square columns.
a. Capital: Standard square.
b. Capital: Architectural square.
c. Capital: Architectural II square.
NOTE ** Retain one of the following three sub-paragraphs to
specify base for square columns.
d. Base: Standard square.
e. Base: Architectural square.
f. Base: Architectural II square.
NOTE ** Retain one of the following six sub-paragraphs to
specify column, capital, and base finish.
3. Finish: Factory primer.
4. Finish: Factory baked-on powder coat enamel, White
color.
5. Finish: Factory baked-on powder coat enamel,
Alabaster color.
6. Finish: Factory baked-on powder coat enamel, Biscuit
color.
7. Finish: Factory baked-on powder coat enamel, Clay
color.
8. Finish: Factory baked-on powder coat enamel, Brown
color.
NOTE ** Retain the following paragraph to specify round
columns.
B. Round Column Assemblies:
1. Column: Fabricated staves of extruded aluminum
conforming to ASTM B 221/ASTM B 221M, Alloy 6063,
Temper T6; with snap-fitting vertical seams for field
assembly:
a. Style: Old South Round Column, fluted vertical
faces.
NOTE ** Retain one of the following nine sub-paragraphs to
specify size and load-bearing capacity of column.
b. Size: 5 inches (127 mm) diameter; 16,000 pounds
( 7,248 kg) load-bearing capacity.
c. Size: 6 inches (152 mm) diameter; 22,000 pounds
( 9,966 kg) load-bearing capacity.
d. Size: 8 inches (203 mm) diameter; 29,000 pounds
(13,137 kg) load-bearing capacity.
e. Size: 10 inches (254 mm) diameter; 21,000 pounds
( 9,513 kg) load-bearing capacity.
f. Size: 12 inches (305 mm) diameter; 28,000 pounds
(12,684 kg) load-bearing capacity.
g. Size: 15 inches (381 mm) diameter; 31,000 pounds
(14,043 kg) load-bearing capacity.
h. Size: 18 inches (457 mm) diameter; 31,000 pounds
(14,043 kg) load-bearing capacity.
i. Size: 24 inches (609 mm) diameter; 31,000 pounds
(14,043 kg) load-bearing capacity.
NOTE ** Consult with manufacturer for data for 36-inch
diameter column.
j. Size: 36 inches (914 mm) diameter; __,___ pounds
(__,___ kg) load-bearing capacity.
NOTE ** Retain one of the following two sub-paragraphs to
specify column length.
k. Column length: __ feet __ inches (__ m).
l. Column length: Indicated on drawings.
2. Capital and base: Cast of aluminum conforming to
ASTM B 179; size for slip-fit over column:
NOTE ** Retain one of the following four sub-paragraphs to
specify capital for round columns.
a. Capital: Standard round.
b. Capital: Doric round.
c. Capital: Corinthian round.
d. Capital: Scamozzi round.
NOTE ** Retain one of the following two sub-paragraphs to
specify base for round columns.
e. Base: Standard round.
f. Base: Doric round.
NOTE ** Retain one of the following six sub-paragraphs to
specify column, capital, and base finish.
3. Finish: Factory primer.
4. Finish: Factory baked-on powder coat enamel, White
color.
5. Finish: Factory baked-on powder coat enamel,
Alabaster color.
6. Finish: Factory baked-on powder coat enamel, Biscuit
color.
7. Finish: Factory baked-on powder coat enamel, Clay
color.
8. Finish: Factory baked-on powder coat enamel, Brown
color.
NOTE ** Delete the following paragraph if not required for
project.
C. As indicated on shop drawings, provide column sections,
capital, and base fabricated in split components for
retro-fit installation; provide for concealed fastening
of split component halves.
D. Accessories: Provide accessories specified in
manufacturer's instructions or indicated on shop
drawings, including, but not limited to, lally columns,
load distribution plates, angle clips, and fasteners.
PART 3 EXECUTION
3.1 EXAMINATION
A. Verify that heights of locations to receive columns are
in accordance with shop drawings.
B. Installer's Examination:
1. Have installer of this section examine conditions
under which construction activities of this section
are to be performed, then submit written notification
if such conditions are unacceptable.
2. Transmit two copies of installer's report to
Architect within 24 hours of receipt.
3. Beginning construction activities of this section
before unacceptable conditions have been corrected is
prohibited.
4. Beginning construction activities of this section
indicates installer's acceptance of conditions.
3.2 PREPARATION
A. Shore and brace adjacent construction in accordance with
manufacturer's instructions.
3.3 INSTALLATION
A. Install components in accordance with shop drawings and
manufacturer's installation instructions.
B. Remove shoring and bracing immediately after completion
of column installation.
C. Site Tolerances:
1. Maximum variation from indicated location: 1/4 inch
(6 mm).
2. Maximum variation from plumb: 1/4 inch (6 mm) in 10
feet (3 m).
NOTE ** Delete the following paragraph if components are
factory finished.
D. Field Finishing: Specified in Section 09900.
3.4 CLEANING
A. Clean component finishes in accordance with
manufacturer's instructions immediately after
installation; protect finishes from soiling until
Substantial Completion.
3.5 PROTECTION
A. Protect components and component finishes from damage by
subsequent construction activities until Substantial
Completion.
B. Repair damage in accordance with manufacturer's
recommendations; replace units which cannot be repaired
to Architect's acceptance.
END OF SECTION